LMS GPA 20 HD GIN POLE
ALUMINUM LIGHTWEIGHT DESIGNED IN ACCORDANCE WITH ANSI/TIA-322
Manufactured to ANSI/TIA-322
- AWS certified
- U.S. AWS certified welder assembled
- U.S. Certified gin pole AWS welder assembled
- Certified AWS independent U.S. contractor inspected
- AWS D1. 1:2015 structural welding code-steel compliance
- Load Charts are pole specific with matching serial numbers
- 5.0 Analysis and design of gin poles
- 6.0 Gin pole construction
- Round Poles are not man-rated
OSHA required Forms supplied with gin poles we manufacture.
- Annual Pole Certification signed and numbered
- Annual Pole Inspection Report signed and numbered
- VT Visual Welding Inspection Report, done at the time of manufacture
- Mill Report on steel specification ASTM A500, Grade B/C
- Charpy report on steel temperature test to –40 degrees
- PE Stamped Pole specific Load Chart to ANSI/TIA-322 standard, All others are obsolete
Weights
- 88 Lb / 40 Kg Pole Weight
- 288 Lb / 131 Kg Shipping Weight
Gin Pole Classifications
Class | Gross Loading | Load Line Size | Impact Factor Req’d steel wire rope |
A | 0 < 1,000 Lbs | d<= 5/16″ | 1.45 |
B | 1,000 < 3,000 Lbs | 5/16″ < d <= 7/16″ | 1.35 |
C | 3,000 < 10,000 Lbs | 7/16″ < d <= 9/16″ | 1.25 |
D | 10,000 + Lbs | d > 9/16″ | 1.20 |
All gin poles using a load line other than steel shall be classified as class A Gin Poles for all load line diameters.
We do not supply any accessory hardware or assembly bolts. Use 1×2.5 A325 Structure bolts, washers and nuts only. Remember to inspect before re-using.
Complete records of pole inspections and record of Magnetic particle inspection shall be performed on 10% of the welded connections every 10 years. Annual inspections reports shall be maintained for a minimum of two years. All gin pole operations must be in compliance with the latest revision of ANSI/TIA-322 and the OSHA CPL 2-1.36, Maintain your required documents along with work plan, engineer sign off for each specific job.