LMS PT 18 GIN POLE

LMS PT 18 Gin Pole manufacturing, servicing, inspections, and repairs have been the primary source for these services for all of the Americas since 2011.  We manufacture the finest Gin Poles in the world with a 100% safety rating worldwide.  LMS Gin Poles are manufactured with steel or aluminum in all sizes. Custom models build for elevator transport for rooftop antennas and towers.  Poles are built are round poles, (GP) triangle poles, (PT), and square poles with jump tracks, (PS). All our poles are Electrostatic coated for long life and ease of handling and safety. You can also find Landa Mobile Systems towers HERE You can also find other LMS news HERE

Manufactured to ANSI/TIA-322 

  • AWS Certified
  • U.S. AWS Certified welder assembled
  • U.S. Certified Gin Pole AWS welder assembled
  • Certified AWS independent contractor inspected
  • AWS D1.1:2015 Structural welding code-steel
  • Load charts are pole-specific with matching serial numbers
  • 5.0   Analysis and Design of Gin Poles
  • 6.0   Gin Pole Construction
  • Metalized surface
  • Base end roller end
  • Double sheave rooster head
  • Guy tower base end option
  • Jump Track Option
  • Optional Sheaves

OSHA required Forms, supplied with all LMS gin poles we manufacture.

  • Annual Pole Certification signed and numbered.
  • Annual Pole Inspection Report signed and numbered.
  • VT Visual Welding Inspection Report, done at the time of manufacture
  • Mill Report on steel specification ASTM A500, Grade B/C
  • Charpy report on steel temperature test to –40 degrees
  • PE Stamped Pole specific Load Chart

Weights

  • 65 Lb / 29 Kg Head section 
  • 350 Lb / 159 Kg 20′ Sections 
  • 110 Lb / 50 Kg Tail section
  • 87 Lb / 39 Kg Rooster head and bearing 

Jump Track option

  • 78″ Long
  • 16.5″ Wide
  • 80 Lb

Sheave options 

  • Sheave 7/16″ groove, 8″ diameter
  • Sheave 5/8″ groove, 8″ diameter
  • Sheave 3/8″ groove, 8″ diameter

OPTIONAL SST (CHICAGO STYLE) ROLLER END

 Class Gross Loading Load Line SizeImpact Factor Req’d steel wire rope
A0 < 1,000 Lbsd<= 5/16″1.45
B1,000 < 3,000 Lbs5/16″ < d <= 7/16″1.35
C3,000 < 10,000 Lbs7/16″ < d <= 9/16″1.25
D10,000 + Lbsd > 9/16″1.20

Pole Charts 64′ & 84′ Sample Triangle Gin Pole Load Charts

Tilted Pole Charts 64′ & 84′ Sample Triangle Gin Pole Load Charts

Pole Charts 104′ 1part line Sample Triangle Gin Pole Load Charts

Tilted Pole Charts 104′

Load charts are pole-specific with serial numbers. Serial numbers on Pulleys must match the serial number of the Gin Pole. This will be required to complete the annual Gin Pole Inspection.  All gin poles using a load line other than steel shall be classified as class A Gin Poles for all load line diameters.

We do not supply any accessory hardware or assembly bolts, shackles, or any attaching hardware. Use 3/4″×2.5 A325 Structural bolts, washers, and nuts only. Remember to inspect before re-using.

Complete records of pole inspections and history of Magnetic particle inspection. Mag particle inspection shall be performed on 10% of the welded connections every 10 years. Annual inspection reports shall be maintained for a minimum of two years. All gin pole operations must comply with the latest ANSI/TIA-322 and the OSHA CPL 2-1.36. Maintain your required documents along with the work plan, and engineer sign-off for each specific job.