Landa Mobile Systems LLC pagelmslogobanner.jpg?zoom=0 LMS GP 20 HCRE GIN POLE

LMS GP 20 HDHCRE GIN POLE

Our heaviest duty round pole consists of a 3 Section slip joint for hand carries, coupled with a rooster head and roller end. 

LMS GP 20 HDHCRE Gin Pole manufacturing, servicing, inspections, and repairs we are the primary source for these services for all of the Americas since 2011.  We manufacture the finest Gin Poles in the world with a 100% safety rating worldwide, LMS Gin Poles are manufactured with steel or aluminum in all sizes. Custom models build for elevator transport for rooftop antennas and towers.  Poles are built are round poles, (GP) triangle poles, (PT), and square poles with jump tracks, (PS). Our poles are Electrostatic coated for long life and ease of handling and safety. You can also find Landa Mobile Systems towers HERE You can also find other LMS news HERE

Manufactured to ANSI/TIA-322

  • AWS Certified
  • U.S. AWS Certified welder assembled
  • U.S. Certified Gin Pole AWS welder assembled
  • Certified AWS independent U.S. contractor inspected
  • AWS D1.1:2015 structural welding code-steel compliance
  • Load charts are pole specific with matching serial numbers
  • 5.0   Analysis and design of Gin Poles
  • 6.0   Gin Pole construction
  • Rooster head/ Chicago end option O
  • Metalized surface
  • Round poles are not man-rated

Weights

  • 375 Lb / 170 Kg Pole weight
  • 20 Lb / 9 Kg  slip rooster head
  • 118 Lb / 53 Kg  top section
  • 122 Lb / 55 Kg  midsection with slip
  • 115 Lb / 52 Kg end section w/o slip and tail roller
  • 207 Lb / 94 Kg Wood shipping crate

OSHA required Forms supplied with all LMS Gin Poles we manufacture.

  • Annual Pole Certification signed and numbered
  • Annual Pole Inspection Report signed and numbered
  • VT Visual Welding Inspection Report, done at the time of manufacture
  • Mill Report on steel specification ASTM A500, Grade B/C
  • Charpy report on steel temperature test to –40 degrees
  • PE Stamped Pole specific Load Chart to ANSI/TIA-322 standard.

Gin Pole Classifications

 Class Gross Loading Load Line SizeImpact Factor Req’d steel wire rope
A0 < 1,000 Lbsd<= 5/16″1.45
B1,000 < 3,000 Lbs5/16″ < d <= 7/16″1.35
C3,000 < 10,000 Lbs7/16″ < d <= 9/16″1.25
D10,000 + Lbsd > 9/16″1.20
Serial numbers on Pulleys must match the serial number of the Gin Pole. This will be required to complete the annual Gin Pole Inspection. All gin poles using a load line other than steel shall be classified as class A Gin Poles for all load line diameters.

We do not supply any accessory hardware or assembly bolts. Use 1×2.5 A325 Structure bolts, washers and nuts only. Remember to inspect before re-using

Certified Green Gin Poles are manufactured 100% from the USA recycled steel.

Certified SDVOSB | Minority owned company

Facility AWS D1.1 Certified, and 100% US Certified Welders welding to AWS, Certified 100% (AWS) D1.1 independent contractor inspected before leaving our facility. Towers are 100% hot dipped galvanized finished to EN ISO 1461/ASTM A123/CSA G164 and ANSI/EIA-TIA-222 G, per section 107 and CSA S37 standards. Steel is ASTM A500, grade B/C.  All products manufactured are Engineered and warranted. We have become the finest manufacturer of Gin Poles, Portable Towers, Climber Training Towers, Oil and Gas Flare Towers, and Portable Shelters in the Americas, thanks to team efforts and most important our customer support. “Service-disabled veteran-owned company built in America by Americans.” Minority owner and plant located in the HUB zone.  Support our efforts as we support your freedom.

Landa Mobile Systems LLC supports and is in compliance with affirmative action obligations on behalf of minorities, women, protected veterans, and individuals with disabilities. Landa Mobile Systems, LLC complies fully with Executive Order 11246 and the applicable regulations of 41 CFR Part 60-1,-2; Section 503 of the Rehabilitation Act and the applicable regulations contained in 41 C.F.R. 60-741; as well as the Vietnam Era Veterans’ Readjustment Assistance Act and the applicable regulations contained in 41 C.F.R. 60-300.