LMS PT 15 GIN POLE

Manufactured to ANSI/TIA-322 

  • AWS Certified 
  • U.S. AWS Certified welder assembled 
  • U.S. Certified Gin Pole AWS welder assembled 
  • Certified AWS independent U.S. contractor inspected 
  • AWS D1.1:2015 Structural welding code-steel compliance 
  • Load charts are pole specific with matching serial numbers 
  • 5.0   Analysis and design of Gin Poles 
  • 6.0   Gin Pole construction
  • Rooster head / Chicago end option 
  • Metalized surface 
  • Single sheave Gin Pole Rooster head 
  • 12″ Sheave will accommodate 3/4″ double braided rope as well

Weights

  • 146 Lb / 66 Kg head section
  • 140 Lb / 64 Kg sections 10′
  • 170 Lb / 77 Kg Tail section
  • 50 Lb / 463 Kg Shipping weight
  • 1020 Lb / 463 Kg shipping weight
  • 580 Lb / 263 Kg crate weight
  • 1600 Lb / 726 Kg total weight

OSHA required Forms supplied with all LMS Gin Poles we manufacture.

  • Annual Pole Certification signed and numbered
  • Annual Pole Inspection Report signed and numbered
  • VT Visual Welding Inspection Report, done at time of manufacture
  • Mill Report on steel specification ASTM A500, Grade B/C
  • Charpy report on steel temperature test to –40 degrees
  • PE Stamped Pole specific Load Chart

LMS PT 15 Sheave options

LMS PT 15 Sheave  1/2″ OEM replacement 1/2″ groove, 12″ diameter. Serial numbered to match pole now required for all to pass inspection.

LMS PT 15 Sheave 5/8″ OEM replacement 5/8″ groove, 12″ diameter. Serial numbered to match pole now required for all to pass inspection.

LMS PT 15 Sheave 3/4″  Sheave 3/4″ OEM replacement 3/4″ groove, 12″ diameter. Serial numbered to match pole now required for all to pass inspection.

Gin Pole Classifications

 Class Gross Loading Load Line SizeImpact Factor Req’d steel wire rope
A0 < 1,000 Lbsd<= 5/16″1.45
B1,000 < 3,000 Lbs5/16″ < d <= 7/16″1.35
C3,000 < 10,000 Lbs7/16″ < d <= 9/16″1.25
D10,000 + Lbsd > 9/16″1.20
 
Serial numbers on Pulleys must match the serial number of the Gin Pole. This will be required to complete the annual Gin Pole Inspection. All gin poles using a load line other than steel shall be classified as class A Gin Poles for all load line diameters.

We do not supply any accessory hardware or assembly bolts. Use 1×2.5 A325 Structure bolts, washers and nuts only. Remember to inspect before re-using.

Serial numbers on Pulleys must match the serial number of the Gin Pole. This will be required to complete the annual Gin Pole Inspection. All gin poles using a load line other than steel shall be classified as class A Gin Poles for all load line diameters.

Complete records of pole inspections and record of Magnetic particle inspection shall be performed on 10% of the welded connections every 10 years. Annual inspections reports shall be maintained for a minimum of two years. All gin pole operations must be in compliance with the latest revision of ANSI/TIA-322 and the OSHA CPL 2-1.36, Maintain your required documents along with work plan, engineer sign off for each specific job.