Landa Mobile Systems Logo

LMS PT 12 HD GIN POLE

LMS PT 12 HD Gin Pole manufacturing, servicing, inspections, and repairs we are the primary source for these services for all of the Americas since 2011.  We manufacture the finest Gin Poles in the world with a 100% safety rating worldwide, LMS Gin Poles are manufactured with steel or aluminum in all sizes. Custom models build for elevator transport for rooftop antennas and towers.  Poles are built are round poles, (GP) triangle poles, (PT), and square poles with jump tracks, (PS). Our poles are Electrostatic coated for long life and ease of handling and safety. You can also find Landa Mobile Systems towers HERE You can also find other LMS news HERE

Manufactured to ANSI/TIA-322 

  • AWS Certified
  • U.S. AWS Certified welder assembled
  • U.S. Certified Gin Pole AWS welder assembled
  • Certified AWS independent U.S. contractor inspected
  • AWS D1.1:2015 Structural welding code-steel compliance
  • Load charts are pole specific with matching serial numbers
  • 5.0   Analysis and design of Gin Poles
  • 6.0   Gin Pole construction
  • Sheave Standard Rooster head option
  • Metalized surface
  • 3 Ea 10Ft / 3.05m in length Sections, optional additional sections up to 64′
  • Jump tracks available for all PT and PS models

Weights

  • 177 Lb / 84.2 Kg Top Section 10′
  • 170 Lb / 77 Kg Mid sections 3ea., 10′
  • 190 Lb / 86 Kg tail section, 10.’
  • 66 Lb / 29.9 Kg non-swingarm rooster head OPTION, 12.”

OSHA required Forms supplied with all LMS Gin Poles we manufacture.

  • Annual Pole Certification signed and numbered.
  • Annual Pole Inspection Report signed and numbered.
  • VT Visual Welding Inspection Report, done at the time of manufacture
  • Mill Report on steel specification ASTM A500, Grade B/C
  • Charpy report on steel temperature test to –40 degrees
  • PE Stamped Pole specific Load Chart

LMS PT 12 HD gin pole Sheave Options, Serial numbered to match pole now required for all to pass inspection.

LMS PT 12 SA Rooster Head is interchangeable with the HD head above.

  • OEM replacement 7/16″ groove 10″ diameter
  • OEM replacement 5/8″ groove 10″ diameter
  • OEM replacement 3/8″ groove 10″ diameter

Swingarm head we can supply

  • OEM replacement 1/2″ groove, 6″ diameter, 2 ea
  • OEM replacement 5/8″ groove 6″ diameter, 2 ea
  • OEM replacement 3/8″ groove 6″ diameter, 2 ea

  LMS PT 12 HD GIN POLE LOAD CHARTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This Gin-Pole rooster head has the quality you would expect to receive with any Landa Product. This pole is the only pole with interchangeable heads and load charts for each configuration.  

Sample Triangle Gin Pole Load Charts

Gin Pole Classifications

 Class Gross Loading Load Line SizeImpact Factor Req’d steel wire rope.
A0 < 1,000 Lbsd<= 5/16″1.45
B1,000 < 3,000 Lbs5/16″ < d <= 7/16″1.35
C3,000 < 10,000 Lbs7/16″ < d <= 9/16″1.25
D10,000 + Lbsd > 9/16″1.20
Serial numbers on Pulleys must match the serial number of the Gin Pole. This will be required to complete the annual Gin Pole Inspection. All gin poles using a load line other than steel shall be classified as class A Gin Poles for all load line diameters.

We do not supply any accessory hardware or assembly bolts. Use 1×2.5 A325 Structural bolts, washers, and nuts only. Remember to inspect before re-using.

Complete records of pole inspections and history of Magnetic particle inspection shall be performed on 10% of the welded connections every 10 years. Annual inspection reports shall be maintained for a minimum of two years. All gin pole operations must comply with the latest ANSI/TIA-322 and the OSHA CPL 2-1.36. Maintain your required documents along with the work plan, engineer sign-off for each specific job.

Certified Green Gin Poles are manufactured 100% from USA recycled steel.